71
The control panel displays [ E ]:
The electronic system is defective.
Disconnect and reconnect the hob.
Call after sales service.
One or all cooking zone(s) are cut off:
The safety system functioned.
This system works when you forgot to switch off the cooking zone.
One or more sensitive touch keys are covered.
The pan is empty and its bottom overheated.
The hob also has an automatic reduction of the power level (see Booster function), and is
switched off automatically when there is a possibility of overheating.
The ventilation system is still working after switching off the hob:
This is not a failure, the fan continues to protect the electronic device.
The fan stops automatically.
The automatic cooking system does not start:
The cooking zone is still hot [ H ].
The highest Booster level is set [ 9 ].
The control panel displays [ U ]:
See chapter “Keep warm“.
The control panel displays [ II ]:
See chapter “Stop&Go“.
The control panel displays [ ]:
See chapter “Grill Function“.
The control panel displays [
] or [ Er03 ]:
An object or liquid covers the control keys. The symbol disappears as soon as the key is
released or cleaned.
The control panel displays [ E2 ]:
The hob is overheated, let it cool and then turn it on again.
The control panel displays [ E8 ]:
The air inlet of the ventilator is obstructed, release it.
The control panel displays [ U400 ]:
The hob is not connected to the network. Check the connection and reconnect the hob.
The control panel displays [ Er47 ]:
The hob is not connected to the network. Check the connection and reconnect the hob.
If one of the symbols above persists, call the SAV.