16 – Inepro Metering – PRO Series
6.10 Setting the total (combined) energy calculation
The meter allows you to display the total energy (usage) shown on the display in accordance to different
calculation methods.
indicating that the total energy is the sum of forward - reverse
To change the calculation method used, please use the infra-red eye, which can be bought separately
and software which can be downloaded via the website of Inepro. On how to use the infra-red eye to
read out values and change settings, a separate manual is available. For this, please contact your local
distributor or Inepro Metering bv.
You can use the following calculation methods for total energy as follows:
Code Total (active) energy
C-01 Forward only
C-04 Reverse only
C-05 Forward + Reverse
C-06 Reverse – Forward
C-09 Forward – Reverse
C-10 Forward – Reverse
6.11 Communicating via the M-bus output(PRO380-Mb only)
The meter is equipped with an M-bus port, the data can be read out via this port. The communication
protocol conforms to the EN13757-3 standard.
The meter can communicate with your PC. In order to read out the meter registers first install and
configure the PC software. Use an M-bus level converter to connect the PC and the meter. The cable
should be connected to terminals 22 and 23. The default primary address of the meter is 001. Secondary
addressing is based on the serial number of the meter (last 8 digits).
Note: For more information, see appendix 2
6.12 Communicating via the Modbus output(PRO380-Mod only)
The meter can communicate with your PC. In order to read out the meter registers first install and
configure the PC software. Use an RS485 level converter to connect the PC and the meter. The cable
should be connected to terminals 22 and 23. The default communication address of the meter is 001.
Note: For more information, see appendix 3