Page 18
Trouble Shooting
Issues
Reasons
Flame goes out
Bumpy noise in ignition
Yellow flame
Abnormal smell
Low temperature of
water at ”high” position
High temperature of
water at ”low” position
Burning after closing the
water valve
Flame out and no reaction
in several minutes
Solutions
Gas valve not open
Turn on main valve or replace the
gas valve
Gas valve half open
Turn on the main valve
Air in the gas pipe
Purge clean the air and restart
Unsuitable
Pressure Gas
High
Contact the gas supplier
Low
Cold water valve closed
Turn on the water supply main
valve
Freezing
Use after defreeze
Low water pressure
Call running water supplier to
check water pressure, then clean
the filter
Water temperature
control mistake
Turn the water flow and gas tap
properly
Insufficient air supply
Open the ventilation hole to let
enough fresh air in
Power shortage
Replace the batteries
Burner clogged
Contact the service center
Heat exchanger clogged
Contact the service center
Water valve reset failure
Contact the service center
Sparking electrode
dislocation
Contact the service center
Exhaust pipe clogged
Remove blockage
Overheat protection
Set a reasonable output water
temperature

Related product manuals