Page 18
Trouble Shooting
Issues
Reasons
Flame goes out
Bumpy noise in ignition
Yellow flame
Abnormal smell
Low temperature of
water at ”high” position
High temperature of
water at ”low” position
Burning after closing the
water valve
Flame out and no reaction
in several minutes
Solutions
Gas valve not open
Turn on main valve or replace the
gas valve
Gas valve half open
●
●
Turn on the main valve
Air in the gas pipe
●
Purge clean the air and restart
Unsuitable
Pressure Gas
High
●
●
●
●
Contact the gas supplier
Low
●
●
Cold water valve closed
Turn on the water supply main
valve
Freezing
Use after defreeze
Low water pressure
●
●
●
Call running water supplier to
check water pressure, then clean
the filter
Water temperature
control mistake
●
●
Turn the water flow and gas tap
properly
Insufficient air supply
●
●
●
●
Open the ventilation hole to let
enough fresh air in
Power shortage
●
Replace the batteries
Burner clogged
●
●
●
Contact the service center
Heat exchanger clogged
●
●
●
●
●
Contact the service center
Water valve reset failure
●
●
Contact the service center
Sparking electrode
dislocation
●
Contact the service center
Exhaust pipe clogged
●
●
Remove blockage
Overheat protection
●
●
Set a reasonable output water
temperature