IMPORTANT SAFETY INSTRUCTIONS
The utilized voltages by this UPS may be hazardous. Do not attempt to disassemble
the unit. The unit contains no user replaceable parts. Only authorized service
personnel may perform repairs.
Internal battery voltage is 12V DC per one battery. Sealed, lead-acid, 6 cells battery.
Connection to any other type of receptacle other than a two-pole, three-wire grounded
receptacle may result in shock hazard as well as violate local electrical codes.
In the event of an emergency, press the “OFF” button and disconnect the power cord
from the AC power supply to properly disable the UPS.
DO NOT allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit.
This unit intended for installation in a controlled environment (temperature controlled,
indoor area free of conductive contaminants). Avoid installing the UPS in location
where there is standing or running water, or excessive humidity.
DO NOT plug the UPS input into its own output.
DO NOT attach a power strip or surge suppressor to the UPS.
DO NOT attach non-computer-related items, such as medical equipment, life-support
equipment, microwave ovens, or vacuum cleaners to UPS
To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting
appliances such as space heaters or furnaces.
Unplug the UPS prior for cleaning and do not use liquid or spray detergent.
DO NOT dispose of batteries in a fire as they may explode.
DO NOT open or mutilate the battery or batteries. Released electrolyte is harmful to
the skin and eyes. It may be toxic.
A battery can present a risk of electrical shock and high short circuit current. The
following precautions should be taken when working on batteries :
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries. Disconnect charging source prior
to connecting or disconnecting battery terminal.
Servicing of batteries should be performed or supervised by experienced personnel
about batteries and the required precautions should be taken. Keep unauthorized
personnel away from batteries.
When replacing batteries, replace with the same number of the sealed lead-acid
batteries.
The socket-outlet shall be installed near the equipment and easily accessible.
With the installation of the UPS, it should be prevented that the sum of (UPS and) the
connected (load) leakage current exceeds 3.5mA.
This pluggable type A equipment with battery installed by the supplier is operator
installable and may be operated by laymen.
Attention!! Hazardous through electric shock. Also with disconnection of this unit
from the mains, hazardous voltage still may be accessible through supply from battery.
The battery supply should be therefore disconnected from the plus and minus poles of
the battery connectors when maintenance or service work inside of the UPS is
necessary.