EonStor DS S12/S16/S24 Series Hardware Manual
For JBODs S12S-J1
000G and S16S-J1000R/S
RAID Models JBOD Configuration
S12E-G1140
S12F-G1440
S12F-G1842
S12S-J1000-G Single-controller; single path
S16E-G1140
S16F-G1440
S16F-G1840
S24F-G1440
S24F-G1840
S16S-J1000-S Single-controller; single path
S16F-R1440
S16F-R1840
S24F-R1440
S24F-R1840
S16S-J1000-R Dual-controller; fault-tolerant paths
There is a rotary ID switch on every expansion enclosure that is manually configured
using a flat blade screwdriver.
Configuring enclosure IDs:
The configurable IDs for JBODs are from 1 to 6. Usually the numbering starts
from the one closest to the managing RAID enclosure.
The S12/S16/S24 RAID subsystems described in this manual connect to a
maximum of 6 JBODs.
Make sure a unique ID is configured on each JBOD so that the SAS WWN
addresses of disk drives can be properly assigned. RAID system firmware
automatically manages these addresses.