INIM SmartLight Series - User Manual

INIM SmartLight Series
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN 54-2
EN 54-4
EN 12094-1
0051-CPD-0222
0051-CPD-0223
SmartLight
Analogue fire alarm control panel
Extinguishant system control panel
Installation and programming manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INIM SmartLight Series and is the answer not in the manual?

Summary

Chapter 2 General Information

2.8 System Testing and Recommendations

Provides guidance on regular system testing and important recommendations for optimal performance.

2.15 Safety Laws

2.15.1 Compliancy and 2.15.2 Device Handling

Covers system compliancy standards and critical procedures for safely handling electronic components.

Chapter 5 User Interface

5.1 SmartLight Panel Frontplate and Commands

Details the frontplate layout, available commands, and their functions based on access level.

Chapter 6 Installation Instructions

6.1 Accessory Module Installation and 6.2 Wall Mounting

Covers the installation of accessory modules and the process of wall mounting the control panel and repeaters.

6.3 Connecting the Loop

Provides instructions for connecting devices to the system's loop circuit, including 2 and 4 wire configurations.

6.5.2 Setting RS485 Device Addresses

Details the procedure for setting unique addresses for devices connected to the RS485 BUS using DIP switches.

6.8 Connecting the Extinguishant Module (Optional)

Provides detailed wiring diagrams for connecting the optional gas extinguishant module.

6.10 Connecting the Mains

Details the connection of the primary 230 Vac power supply to the system.

6.11 Connecting the Batteries

Explains the series connection of batteries for the system's secondary power supply.

6.12 Thermal Probe

Chapter 7 System Power Up and Configuration

7.1 Testing Wiring Integrity

Procedures to verify wiring integrity and isolation before powering up the system.

7.3 System Power Up

Step-by-step guide for powering up the system, including battery connection and initial checks.

Chapter 8 Programming from the Panel

Chapter 9 Preparing the Programming Data

Chapter 10 Configuring the Loop

Chapter 11 Programming Fire Detection Points

11.1 Fire-Detection Point Configuration

Setting up fire detection points, including general parameters like address, device type, and zone assignment.

Chapter 12 Programming the Extinguishant Module

12.2 Module Operating Principles

Configuring parameters for the extinguishant module, such as mask zones, confirmation settings, and timing.

Chapter 13 Configuring RS485 BUS Devices

Chapter 16 Maintenance

Chapter 17 Diagnostics and Fault Solutions

17.1 Open I;O and 17.2 Shorted I;O Faults

Identifying and resolving common input/output faults such as open circuits and short circuits on terminals.

17.3 Loop Faults

Troubleshooting various loop faults including short-circuits, open loops, and device communication issues.

17.5 Repeater Faults and 17.6 Battery Faults

Troubleshooting issues related to repeater communication and battery status, including disconnection and low battery.

Appendix A Enea Series Devices

INIM SmartLight Series Specifications

General IconGeneral
BrandINIM
ModelSmartLight Series
CategoryControl Panel
LanguageEnglish