INIM SmartLight/G - User Manual

INIM SmartLight/G
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN 54-2
EN 54-4
EN 12094-1
0051-CPD-0222
0051-CPD-0223
SmartLight
Analogue fire alarm control panel
Extinguishant system control panel
Installation and programming manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INIM SmartLight/G and is the answer not in the manual?

Summary

Chapter 4 Technical Description

4.2 Technical Specifications

Lists electrical specifications, dimensions, and weight of the control panel and its modules.

Chapter 5 User Interface

5.1 SmartLight Panel Frontplate and Commands

Describes the frontplate layout, commands, and LED indicators for system status.

Chapter 6 Installation Instructions

6.1 Installing the Extinguishant Module

Step-by-step guide for installing the optional extinguishant module onto the motherboard.

6.3 Loop Connection and Limitations

Details loop wiring methods, limitations, cable requirements, and fire code guidelines.

6.5 RS485 BUS Connection and Addressing

Describes connecting repeaters and power stations via RS485 BUS and setting device addresses.

6.6 Fault Signaling Outputs

Details connecting the normally-open dry contact and supervised fault signaling outputs.

6.7 Alarm Signaling Output

Instructions for wiring the silenceable supervised alarm signaling output.

6.8 Extinguishant Module Connection

Wiring diagrams and explanations for extinguishant module inputs and outputs.

6.10 Mains Power Connection

Instructions for connecting the main power supply, including technical specifications and wiring.

6.11 Battery Connection

Guidance on connecting the two 12V batteries in series and battery monitoring processes.

6.12 Thermal Probe Installation

Explains how to connect and use the thermal probe for battery temperature regulation.

Chapter 7 Powering Up and System Configuration

7.1 Wiring Integrity Testing

Procedure to test wiring integrity, isolation, and cable separation before powering up.

7.2 RS232 PC Serial Link Connection

Instructions for connecting the PC to the panel using an RS232 serial link.

7.3 System Power Up Procedure

Steps for connecting batteries and powering up the system, including polarity checks.

Chapter 8 Programming from the Panel

Chapter 9 Programming Data Preparation

9.2 Delays and Times Configuration

Configures parameters like mains failure delay, dialer delay, verify time, silence time, and filter time.

9.4 Zone Definition

Allows defining zones, assigning points, and setting zone descriptions and pre-alarm times.

9.6 Timer Settings

Defines timer intervals, dates, and special days for automatic time-management operations.

Chapter 10 Loop Configuration

10.1 Defining Loop Typology

Selects the loop type (INIM, Argus, Apollo) and wiring method (2 or 4 wires).

10.2 Manual Device Addition;Removal

Describes how to manually add or remove devices, assign addresses, and set device types.

Chapter 11 Fire Detection Point Programming

Chapter 12 Extinguishant Module Programming

12.1 Configuring the Extinguishant Module

Determines how many extinguishant modules are connected to the panel.

12.2 Module Programming Parameters

Sets parameters like mask zone, confirm extinguish, wait for pressure switch, and pre-extinguish time.

12.3 Extinction Point Programming

Configures extinction points, their general parameters, input actions, and signals that activate points.

Chapter 13 RS485 BUS Device Configuration

Chapter 14 Programming Session Closure

Chapter 15 SmartLeague Software

Chapter 16 Maintenance

Chapter 17 Diagnostics and Fault Solutions

17.1 Open I;O Fault Diagnosis

Troubleshooting steps for 'Open I/O' faults, checking EOL resistor connections and integrity.

17.2 Shorted I;O Fault Diagnosis

Troubleshooting steps for 'Shorted I/O' faults, checking device connections and cable sections.

17.3 Loop Faults

Diagnoses loop faults like short-circuits, open isolators, and interrupted cables with remedies.

17.6 Battery Faults

Diagnoses battery faults like disconnection or low battery status, with troubleshooting steps.

INIM SmartLight/G Specifications

General IconGeneral
Number of loops1
Event log1000 events
Protection RatingIP30
LED IndicationYes
Battery capacity7Ah
Communication ProtocolRS485