Do you have a question about the INIM SmartLight/G and is the answer not in the manual?
Lists electrical specifications, dimensions, and weight of the control panel and its modules.
Describes the frontplate layout, commands, and LED indicators for system status.
Step-by-step guide for installing the optional extinguishant module onto the motherboard.
Details loop wiring methods, limitations, cable requirements, and fire code guidelines.
Describes connecting repeaters and power stations via RS485 BUS and setting device addresses.
Details connecting the normally-open dry contact and supervised fault signaling outputs.
Instructions for wiring the silenceable supervised alarm signaling output.
Wiring diagrams and explanations for extinguishant module inputs and outputs.
Instructions for connecting the main power supply, including technical specifications and wiring.
Guidance on connecting the two 12V batteries in series and battery monitoring processes.
Explains how to connect and use the thermal probe for battery temperature regulation.
Procedure to test wiring integrity, isolation, and cable separation before powering up.
Instructions for connecting the PC to the panel using an RS232 serial link.
Steps for connecting batteries and powering up the system, including polarity checks.
Configures parameters like mains failure delay, dialer delay, verify time, silence time, and filter time.
Allows defining zones, assigning points, and setting zone descriptions and pre-alarm times.
Defines timer intervals, dates, and special days for automatic time-management operations.
Selects the loop type (INIM, Argus, Apollo) and wiring method (2 or 4 wires).
Describes how to manually add or remove devices, assign addresses, and set device types.
Determines how many extinguishant modules are connected to the panel.
Sets parameters like mask zone, confirm extinguish, wait for pressure switch, and pre-extinguish time.
Configures extinction points, their general parameters, input actions, and signals that activate points.
Troubleshooting steps for 'Open I/O' faults, checking EOL resistor connections and integrity.
Troubleshooting steps for 'Shorted I/O' faults, checking device connections and cable sections.
Diagnoses loop faults like short-circuits, open isolators, and interrupted cables with remedies.
Diagnoses battery faults like disconnection or low battery status, with troubleshooting steps.
| Number of loops | 1 |
|---|---|
| Event log | 1000 events |
| Protection Rating | IP30 |
| LED Indication | Yes |
| Battery capacity | 7Ah |
| Communication Protocol | RS485 |