EasyManua.ls Logo

INIM SmartLight/S - User Manual

INIM SmartLight/S
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN 54-2
EN 54-4
EN 12094-1
0051-CPD-0222
0051-CPD-0223
SmartLight
Analogue fire alarm control panel
Extinguishant system control panel
Installation and programming manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INIM SmartLight/S and is the answer not in the manual?

Summary

Chapter 1: Overview

Chapter 3: Device Management

Chapter 4: Technical Description

4.2 Technical Specifications

Lists key technical specifications like power, dimensions, and operating temperature.

Chapter 5: User Interface

5.1 Panel Frontplate and Commands

Describes the frontplate layout, commands, and LED indicators on the main panel.

Chapter 6: Installation Instructions

6.3 Connecting the Loop

Explains how to connect devices to the loop circuit using 2 or 4 wire connections.

6.10 Connecting the Mains

Instructions for connecting the primary power supply (230 Vac).

6.11 Connecting the Batteries

Guidance on connecting the two 12V batteries in series for the secondary power supply.

Chapter 7: System Power-Up and Configuration

7.1 Testing Wiring Integrity

Checks for wiring integrity, isolation, and correct cable connections before powering up.

7.3 Powering Up the System

Procedures for powering up the system and connecting the batteries correctly.

Chapter 8: Panel Programming

Accessing Panel Programming

Details how to access the programming mode using the programming jumper.

Chapter 9: Programming Data Preparation

9.4 Defining Zones

Guides on defining zones, their descriptions, and associated alarm parameters.

Chapter 10: Loop Configuration

10.1 Defining Loop Typology

Sets the loop type (INIM, Argus, Apollo) and wiring method (2 or 4 wires).

10.2 Adding;Removing Devices

Manual process for adding or removing devices from the loop configuration.

Chapter 11: Fire Detection Point Programming

11.1 Programming Fire Detection Points

Guides on programming individual points for fire detection functions.

Chapter 12: Extinguishant Module Programming

Chapter 13: RS485 BUS Device Configuration

Chapter 14: Closing Programming Session

Chapter 15: SmartLeague Software

Chapter 16: Maintenance Procedures

Chapter 17: Diagnostics and Fault Solutions

17.1 Open I;O Fault

Troubleshooting guide for 'Open I/O' faults on loop connections.

17.2 Shorted I;O Fault

Troubleshooting guide for 'Shorted I/O' faults on loop connections.

INIM SmartLight/S Specifications

General IconGeneral
BrandINIM
ModelSmartLight/S
CategoryControl Panel
LanguageEnglish

Related product manuals