Chapter 5 Function Code Table
- 61 -
Function
Code
Parameter Name Function Description Setting Range Default
b3.27
AI2 min. input For the function and use, see the descriptions of
b3.22 to b3.26.
0.00 V to
b3.29
0.00 V
b3.28 Corresponding setting
of AI2 min. input
0.0% to
100.0%
0.0%
b3.29 AI2 max. input b3.27 to 10.00
V
10.00 V
b3.30 Corresponding setting
of AI2 max. input
0.0% to 100% 100.0%
b3.31 AI2 lter time 0.00s to
10.00s
0.10s
b3.43 AO1 zero offset
coefcient
These two parameters are used to correct the zero
offset of analog output and the output amplitude
deviation. They can also be used to dene the
desired AO curve.
If "b" represents zero offset, "k" represents gain,
"Y" represents actual output, and "X" represents
standard output, the actual output is: Y = kX + b.
The zero offset coefcient 100% of AO1 and AO2
corresponds to 10 V (or 20 mA). The standard
output refers to the value corresponding to the
analog output of 0 to 10 V (or 0 to 20 mA) with no
zero offset or gain adjustment.
For example, if the analog output is used as the
frequency reference, it is expected that the output
is 8 V when the frequency is 0 V, and the output is
3 V at the max. frequency. You need to set the gain
to -0.50 and the zero offset to 80%.
-100.0% to
100.0%
0.0%
b3.44 AO1 gain -10.00 to 10.00 1.00
b3.45 AO2 zero offset
coefcient
-100.0% to
100.0%
0.0%
b3.46 AO2 gain -10.00 to 10.00 1.00
Group b4: Ramp Parameters
b4.00 Acceleration time Acceleration time indicates the time required for the
AC drive to accelerate from 0 to the rated frequency
(A0.04), shown as t1 in the following gure.
Deceleration time indicates the time required for
the AC drive to decelerate from the rated frequency
(A0.04) to 0, shown as t2 in the following gure.
Output
frequency Hz
Rated frequency
Frequency reference
t1 t2
Time (t)
Actual
acceleration time
Actual
deceleration time
0.1s to 600.0s 3.0s
b4.01 Deceleration time