5 Parameter Table
- 23 -
5� Parameter List
5�1 Introduction
Groups F and A include basic and hydraulic function parameters� Group U includes the monitoring function parameters and
extension card communication parameters�
The parameter description tables in this chapter use the following symbols� The symbols in the parameter table are described as follows:
Symbol Meaning
☆
It is possible to modify the parameter with the drive in the stop or in the run status�
★
It is not possible to modify the parameter with the drive in the run status�
● The parameter is the actual measured value and cannot be modied.
* The parameter is a factory parameter and can be set only by the manufacturer�
5�2 Hydraulic Control and Basic Control Parameter List
Para� No� Para� Name Setting Range Unit Default Property
Group A0: Flux Weakening Control
A0-00 Flux weakening method selection 0: by calculation
1: auto adjusted
1 1
★
A0-01 Flux weakening current factor 0 to 500 1 5
☆
A0-02 Pm motor ux weakening depth 0 to 50 % 5
☆
A0-03 Factor of pm motor max� output
torque
20 to 300 % 100
☆
A0-04 Factor of pm motor eld current 40 to 200 % 100
☆
Group A1: PG Card
A1-00 PG card type selection 0: resolver
1: reserved
2: ABZ encoder
1 0
★
A1-02 Encoder installation angle 0�0 to 359�9 ° 0
☆
A1-03 Speed feedback direction 0: same
1: reverse
1 -
★
A1-04 Number of resolver pole-pairs 1 to 50 1 Model
dependent
★
A1-05 Resolver fault detection time 0�000 to 60�000 Sec 2�000
☆
A1-06 Encoder resolution 0 to 65535 1 1024
★
A1-08 Speed sensor interference counts 0 to 60000 1 0
☆
Group A2: CAN Communication
A2-00 Baud rate 0: 20
1: 50
2: 125
3: 250
4: 500
5: 1024
kHz 4
☆
A2-01 CANLink address 1 to 64 1 1
☆
A2-02 CANLink continuous communication
time
0�1 to 600�0 sec 0�3
☆
A2-03 CANLink multi-pump mode selection 0: broadcast
1: multi masters
1 0
☆
A2-04 CANLink slave address 1 0 to 65535 1 0
☆