Appendix
- 307 -
12
B.2  Standard Parameters
Para. No. Para. Name Setting Range Default Property Page
Group F0: Standard Parameters
F0-00 G/P type display 1 : G type
2:  P type
Model 
dependent
ƾ
-
F0-01 Motor 1 control mode 2: V/F control 2
ƾ
-
F0-02 Command source selection 0: Operating panel (keypad & 
display) (LED off)
1: Terminal I/O control (LED on)
6HULDOFRPPV/('ÀDVKLQJ
0
ƿ
1
0
2
 
F0-03 Main frequency reference 
setting channel selection
0: Digital setting (non-retentive at 
power down)
1: Digital setting (retentive at 
power down)
2: AI1
3: AI2
4: AI3
5: Pulse reference
6: Multi-reference
7: Simple PLC
8: PID reference
9: Serial comms.
0
ƾ
1
1
0
 
F0-04 Auxiliary frequency reference 
setting channel selection
0: Digital setting (non-retentive at 
power down)
1: Digital setting (retentive at 
power down)
2: AI1
3: AI2
4: AI3
5: Pulse reference
6: Multi-reference
7: Simple PLC
8: PID reference
9: Serial comms.
0
ƾ
1
3
1
 
F0-05 Base value of range of auxiliary 
frequency reference for Main 
and auxiliary calculation
0: Relative to maximum frequency
1: Relative to main frequency 
reference
0
ƿ
1
3
3
 
F0-06 Range of auxiliary frequency 
reference for main and auxiliary 
calculation
0% to 150% 100%
ƿ
1
3
3