Function Code Table
MD380 User Manual
- 112 -
Function
Code
Parameter Name
Setting Range
Default Property
Group FD: Communication Parameters
FD-00 Baud rate
Unit's digit (Modbus baud rate)
6005 ☆
0: 300 BPs
1: 600 BPs
2: 1200 BPs
3: 2400 BPs
4: 4800 BPs
5: 9600 BPs
6: 19200 BPs
7: 38400 BPs
8: 57600 BPs
9: 115200 BPs
Ten's digit (PROFIBUS-DP baud
rate)
0: 115200 BPs
1: 208300 BPs
2: 256000 BPs
3: 512000 Bps
Hundred's digit (reserved)
Thousand's digit (CANlink baud
rate)
0: 20
1: 50
2: 100
3: 125
4: 250
5: 500
6: 1 M
FD-01 Data format
0: No check, data format <8,N,2>
1: Even parity check, data format
<8,E,1>
2: Odd Parity check, data format
<8,O,1>
3: No check, data format <8,N,1>
Valid for Modbus
0 ☆
FD-02 Local address
0: Broadcast address
1–247
Valid for Modbus, PROFIBUS-DP
and CANlink
1 ☆