Loading...
MD380 User Manual Function Code Table
- 115 -
Function
Code
Parameter Name
Setting Range
Default Property
FP-03
Individualized
parameter display property
Unit's digit (User-dened
parameter display selection)
00
0: Not display
1: Display
Ten's digit (User-modied
parameter display selection)
0: Not display
1: Display
FP-04
Parameter
modication property
0: Modiable
1: Not modiable
0
Group A0: Torque Control and Restricting Parameters
A0-00
Speed/Torque
control selection
0: Speed control
1: Torque control
0
A0-01
Torque setting source in
torque control
0: Digital setting (A0-03)
1: AI1
2: AI2
3: AI3
4: Pulse setting (DI5)
5: Communication setting
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
Full range of values 1–7
corresponds to the digital setting
of A0-03.
0
A0-03
Torque digital setting in
torque control
-200.0%–200.0%
150.0%
A0-05
Forward maximum
frequency in torque control
0.00 Hz to maximum frequency
(F0-10)
50.00 Hz
A0-06
Reverse maximum
frequency in torque control
0.00 Hz to maximum frequency
(F0-10)
50.00 Hz
A0-07
Acceleration time in torque
control
0.00–65000s
0.00s
A0-08
Deceleration time in torque
control
0.00–65000s
0.00s
Group A1: Virtual DI (VDI)/Virtual DO (VDO)
A1-00 VDI1 function selection
0–59
0
A1-01 VDI2 function selection
0–59
0
A1-02 VDI3 function selection
0–59
0
A1-03 VDI4 function selection
0–59
0

Table of Contents