Function Code Table
MD380 User Manual
- 116 -
Function
Code
Parameter Name
Setting Range
Default Property
A1-04 VDI5 function selection
0–59
0 ★
A1-05 VDI state setting mode
Unit's digit (VDI1)
00000 ★
0: Decided by state of VDOx
1: Decided by A1-06
Ten's digit (VDI2)
0, 1 (same as VDI1)
Hundred's digit (VDI3)
0, 1 (same as VDI1)
Thousand's digit (VDI4)
0, 1 (same as VDI1)
Ten thousand's digit (VDI5)
0, 1 (same as VDI1)
A1-06 VDI state selection
Unit's digit (VDI1)
00000 ★
0: Invalid
1: Valid
Ten's digit (VDI2)
0, 1 (same as VDI1)
Hundred's digit (VDI3)
0, 1 (same as VDI1)
Thousand's digit (VDI4)
0, 1 (same as VDI1)
Ten thousand's digit (VDI5)
0, 1 (same as VDI1)
A1-07
Function selection for AI1
used as DI
0–59
0 ★
A1-08
Function selection for AI2
used as DI
0–59
0 ★
A1-09
Function selection for AI3
used as DI
0–59
0 ★
A1-10
State selection for AI used
as DI
Unit's digit (AI1)
000 ★
0: High level valid
1: Low level valid
Ten's digit (AI2)
0, 1 (same as unit's digit)
Hundred's digit (AI3)
0, 1 (same as unit's digit)