Function Code Table                                                                                 
MD380  User  Manual                                                 
- 122 -
Function 
Code
Parameter Name
Setting Range
Default Property
A3-08
Leakage inductive reactance 
(asynchronous motor)
0.01–655.35 mH (AC drive power 
≤ 55 kW)
0.001–65.535 mH (AC drive 
power > 55 kW)
Model 
dependent
★
A3-09
Mutual inductive reactance 
(asynchronous motor)
0.1–6553.5 mH (AC drive power 
≤ 55 kW)
0.01–655.35 mH (AC drive power 
> 55 kW)
Model 
dependent
★
A3-10
No-load current 
(asynchronous motor)
0.01 A to A2-03 (AC drive power 
≤ 55 kW)
0.1 A to A2-03 (AC drive power > 
55 kW)
Model 
dependent
★
A3-16
Stator resistance 
(synchronous motor)
0.001–65.535 Ω (AC drive power 
≤ 55 kW)
0.0001–6.5535 Ω (AC drive 
power > 55 kW)
Model 
dependent
★
A3-17
Shaft D inductance 
(synchronous motor)
0.01–655.35 mH (AC drive power 
≤ 55 kW)
0.001–65.535 mH (AC drive 
power > 55 kW)
Model 
dependent
★
A3-18
Shaft Q inductance 
(synchronous motor)
0.01–655.35 mH (AC drive power 
≤ 55 kW)
0.001–65.535 mH (AC drive 
power > 55 kW)
Model 
dependent
★
A3-20
Back EMF (synchronous 
motor)
0.1–6553.5 V
Model 
dependent
★
A3-27
Encoder pulses per 
revolution
1–65535
1024 ★
A3-28 Encoder type
0: ABZ incremental encoder
1: UVW incremental encoder
2: Resolver
3: SIN/COS encoder
4: Wire-saving UVW encoder
0 ★
A3-30
A, B phase sequence of ABZ 
incremental encoder
0: Forward
1: Reserve
0 ★
A3-31 Encoder installation angle
0.0°–359.9°
0.0° ★
A3-32
U, V, W phase sequence of 
UVW encoder
0: Forward
1: Reverse
0 ★
A3-33
UVW encoder angle offset 0.0°–359.9° 0.0°
★