MD380 User Manual Function Code Table
- 109 -
Function
Code
Parameter Name
Setting Range
Default Property
Group F9: Fault and Protection
F9-00 Motor overload protection
0: Disabled
1: Enabled
1 ƿ
F9-01
Motor overload protection
gain
0.20–10.00
1.00 ƿ
F9-02
Motor overload pending
FRHI¿FLHQW
50%–100%
80% ƿ
F9-03 2YHUYROWDJHVWDOOJDLQ
0–100
0 ƿ
F9-04
2YHUYROWDJHVWDOOSURWHFWLYH
voltage
120%–150%
130% ƿ
F9-05 2YHUFXUUHQWVWDOOJDLQ
0–100
20 ƿ
F9-06
2YHUFXUUHQWVWDOOSURWHFWLYH
current
100%–200%
150% ƿ
F9-07
Short-circuit to ground upon
power-on
0: Disabled
1: Enabled
1 ƿ
F9-09 Auto reset times
0–20
0 ƿ
F9-10 '2DFWLRQGXULQJDXWRUHVHW
0: Not act
1: Act
0 ƿ
F9-11 Delay of auto reset
0.1s–100.0s
1.0s ƿ
F9-12
Power input phase loss
protection/Contactor close
protection
8QLWVGLJLW3RZHULQSXWSKDVH
loss protection
Ten's digit: Contactor close
protection
0: Disabled
1: Enabled
11 ƿ
F9-13
Power output phase loss
protection
0: Disabled
1: Enabled
1 ƿ