Function Code Table
MD380 User Manual
- 110 -
Function
Code
Parameter Name
Setting Range
Default Property
F9-14 1st fault type
0: No fault
1: Reserved
2YHUFXUUHQWGXULQJDFFHOHUDWLRQ
2YHUFXUUHQWGXULQJGHFHOHUDWLRQ
2YHUFXUUHQWDWFRQVWDQWVSHHG
2YHUYROWDJHGXULQJ
acceleration
2YHUYROWDJHGXULQJ
deceleration
2YHUYROWDJHDWFRQVWDQWVSHHG
8: Buffer resistance overload
8QGHUYROWDJH
10: AC drive overload
11: Motor overload
12:Power input phase loss
13: Power output phase loss
14: Module overheat
15: External device fault
16: Communication fault
17: Contactor fault
18: Current detection fault
19: Motor auto-tuning fault
20: Encoder/PG card fault
((3520UHDGZULWHIDXOW
22: AC drive hardware fault
23: Short circuit to ground
24: Reserved
25: Reserved
26: Accumulative running time
reached
8VHUGH¿QHGIDXOW
8VHUGH¿QHGIDXOW
29: Accumulative power-on time
reached
30: Load lost
31: PID feedback lost during
running
40: Fast current limit timeout
41: Motor switchover fault during
running
- ƽ
F9-15 2nd fault type - ƽ