Function Code Table
MD380 User Manual
- 90 -
Function
Code
Parameter Name
Setting Range
Default Property
F4-14
Corresponding setting of AI
curve 1 minimum input
-100.00%–100.0%
0.0%
F4-15 AI curve 1 maximum input
F4-13 to 10.00 V
10.00 V
F4-16
Corresponding setting of AI
curve 1 maximum input
-100.00%–100.0%
100.0%
F4-17 AI1 lter time
0.00–10.00s
0.10s
F4-18 AI curve 2 minimum input
0.00 V to F4-20
0.00 V
F4-19
Corresponding setting of AI
curve 2 minimum input
-100.00%–100.0%
0.0%
F4-20 AI curve 2 maximum input
F4-18 to 10.00 V
10.00 V
F4-21
Corresponding setting of AI
curve 2 maximum input
-100.00%–100.0%
100.0%
F4-22 AI2 lter time
0.00–10.00s
0.10s
F4-23 AI curve 3 minimum input
0.00 V to F4-25
0.00 V
F4-24
Corresponding setting of AI
curve 3 minimum input
-100.00%–100.0%
0.0%
F4-25 AI curve 3 maximum input
F4-23 to 10.00 V
10.00 V
F4-26
Corresponding setting of AI
curve 3 maximum input
-100.00%–100.0%
100.0%
F4-27 AI3 lter time
0.00–10.00s
0.10s
F4-28 Pulse minimum input
0.00 kHz to F4-30
0.00 kHz
F4-29
Corresponding setting of
pulse minimum input
-100.00%–100.0%
0.0%
F4-30 Pulse maximum input
F4-28 to 50.00 kHz
50.00 kHz
F4-31
Corresponding setting of
pulse maximum input
-100.00%–100.0%
100.0%
F4-32 Pulse lter time
0.00–10.00s
0.10s