Technical Data
‑130‑
Item
Specifications
Model: MD520‑2Txxxxx
75(S) 90(S) 110(S) 132(S) 160(S) 200(S)
Heat
dissipation
design
Thermal design power (kW)
(heavy load)
3.56 4.15 4.55 5.33 5.69 6.91
Thermal design power (kW)
(light load)
4.15 4.55 5.33 5.69 6.91 7.61
Air flow (CFM)
627 638.4 722.5 882 645 860
Overvoltage
class
OVCIII
Pollution
degree
PD2
IP rating
IP20
Single phase 200-240 V
Table 7–11 Electrical parameters of T2 models (single phase 200‑240 V)
Item
Specifications
Model: MD520‑2Sxxxxx
0.4B(S) 0.7B(S) 1.5B(S) 2.2B(S)
Structure T2
Output
Power (kW) (heavy load)
0.4 0.75 1.5 2.2
Power (kW) (light load)
0.75 1.5 2.2 3.0
Rated output current (A)
(heavy load)
2.3 4 7 9.6
Rated output current (A)
(light load)
4 7 9.6 12
Output voltage Three phase 0 V to 240 V (subject to input voltage)
Max. output frequency 599 Hz (editable through parameter)
Carrier frequency 0.5 kHz to 16.0 kHz (automatically adjusted according to the load)
Overload capacity
60s at 150% the rated current
Input
Rated input current (A)
(heavy load)
5.4 8.2 14 20
Rated input current (A)
(light load)
8.2 14 20 27
Rated voltage/frequency Single phase 200‑240 V, 50/60 Hz
Allowable voltage
fluctuation range
‑15% to +10% or 170‑264 VAC
Allowable frequency
fluctuation range
±5% or 47.5‑63 Hz
Power supply capacity
(kVA) (heavy load)
1.4 2.2 3.7 6
Power supply capacity
(kVA) (light load)
2.2 3.7 6 9.6