AC Drive Power (kW) Rated Voltage (V) Min. Cable Length (m)
5.5 200500 110
7.5 200500 125
11
200500 150
Models and dimensions (Inovance)
Models and dimensions of recommended Inovance AC output reactors are as follows.
Figure 5‑36 AC output reactor model
Note
The following recommended AC output reactors are applicable only to T1 to T9
models.
For T10 to T12 models, purchase AC output reactors with the model name
containing "‑L".
Table 5–45 Selection of Inovance AC output reactors (three phase 380‑480 V)
Structure AC Drive Model Reactor Model Inductance
(mH)
Loss (W)
T1 MD520‑4T0.4B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T0.7B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T1.1B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T1.5B(S) MD‑OCL‑5‑1.4‑4T‑1% 1.4
MD520‑4T2.2B(S) MD‑OCL‑7‑1.0‑4T‑1% 1.0
MD520‑4T3.0B(S) MD‑OCL‑10‑0.7‑4T‑1% 0.7
T2 MD520‑4T3.7B(S) MD‑OCL‑10‑0.7‑4T‑1% 0.7
MD520‑4T5.5B(S) MD‑OCL‑15‑0.47‑4T‑1% 0.47
T3 MD520‑4T7.5B(S) MD‑OCL‑20‑0.35‑4T‑1% 0.35
MD520‑4T11B(S) MD‑OCL‑30‑0.23‑4T‑1% 0.23
T4 MD520‑4T15B(S) MD‑OCL‑40‑0.18‑4T‑1% 0.18