EasyManuals Logo

Inovance Monarch 220-NICE-L-C-4011 User Manual

Inovance Monarch 220-NICE-L-C-4011
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #231 background imageLoading...
Page #231 background image
6 Parameter Description
-
230
-
F8-14 Bit0 = 0: The communication baud rate between the MCB and HCB is 9600 bps.
F8-14 Bit0 = 1: The communication baud rate between the MCB and HCB is 38400 bps.
Note that only the NICE3000
new
product supports 38400 bps, and the NICE3000 sup-
ports only 9600 bps.
The system automatically determines the communication baud rate, and generally,
you need not set this parameter.
F8-16 is used to set the HCB start address of the back door in opposite door mode.
󶍿
󶍿
but displays the set address of itself, convenient for inspection in the case of wrong
󶍿
38400 bps.
Group F9: Time parameters
Function
Code
Name Setting Range Default Unit Property
F9-00
Idle time before returning
󶍿
0 to 240 10 min
󶍿
When the idle time of the elevator exceeds the setting of this parameter, the elevator
󶍿
Function
Code
Name Setting Range Default Unit Property
F9-01 Car energy-saving time 0 to 240 2 min
󶍽-
cally.
󶍽
the fan and lamp automatically after the time set in this parameter.
Function
Code
Name Setting Range Default Unit Property
F9-02
Motor running time
limit
0 to 45 45 s
It is used to set the running time limit of the motor.
In normal running state, if the continuous motor running time in the same direction
󶍿-
nal is received, the system will perform protection. This parameter is mainly used for
over-time protection in the case of steel rope slipping on the traction sheave.

Table of Contents

Other manuals for Inovance Monarch 220-NICE-L-C-4011

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch 220-NICE-L-C-4011 and is the answer not in the manual?

Inovance Monarch 220-NICE-L-C-4011 Specifications

General IconGeneral
BrandInovance
ModelMonarch 220-NICE-L-C-4011
CategoryController
LanguageEnglish

Related product manuals