Introduction
- 
10
 -
Function Description Remarks
Energy-saving Functions
Car energy-
saving
In car door open holding and door close limit state, after the set time (F9-01) 
fan in the car.
F9-01 "Time for 
fan and lamp 
to be turned 
Energy-saving 
running with 
standby power 
supply
When the normal power supply is interrupted and the emergency power 
supply is used, the system reduces the running speed of the elevator in the 
prerequisite of guaranteeing the smooth running curve.
-
Arrival gong 
disabled at night
Within the set time period, the arrival gong is disabled. Bit4 of F5-33
2  Optional functions
Function Function description Remarks
Door pre-open 
function
In automatic running state, when the elevator speed is smaller than 0.25 m/s 
and the door zone signal is active, the system shorts the door lock by means 
of the shorting door lock circuit relay and outputs the door open signal, 
MCTC-SCB 
required
Micro-leveling
the load change and the car door is not aligned with the ground, which is 
inconvenient for passengers and goods in and out. In this case, the system 
allows the elevator to run to the leveling position in the door open state at the 
re-leveling speed.
MCTC-SCB 
required
Power failure 
emergency 
evacuation
the emergency power supply to implement low-speed self-rescue in the case 
of power failure.
MCTC-ARD-C 
required
Onsite 
commissioning
Function
The system can control and monitor running of elevators by using the NEMS 
software.
-
Commissioning 
by cell phone
The smartphone can be connected to the controller through the external WIFI 
module, and you can commission the elevator, and upload and download 
parameters by using the cell phone.
Special WIFI 
module and 
cell phone 
host computer 
required
Residential 
monitoring
The control system can be connected to the terminal in the monitoring 
direction, and fault state of the elevator.
NEMS software, 
accessories,
and MCTC-MIB 
required
IC card  IC card required
STO
When a fault is detected in the safety circuit, the STO function safety card acts 
torque of the motor.
Special bottom 
and STO 
function card 
MCTC-JCB-A2 
required
Machine-room-
less monitoring
The running state of the elevator inside the shaft is displayed and the function 
of commissioning and burning outside the shaft is implemented through the 
MCTC-MB-A2 monitoring board.
MCTC-MB-A2 
monitoring 
board required