SERVICE WARNINGS AND FAULT DIAGNOSIS
Your boiler is fitted with an intelligent fault diagnosing system and is able to detect various fault
conditions. Some of these are less serious and the machine will continue to operate as normal, while
others are more serious and will disable the unit.
Before calling for service, switch the machine off at the mains supply. Draw-off a small amount of
water and then switch back on after 10 minutes. If the fault does not clear, call technical support for
advice.
Service Warning Codes:
Number of Flashes
Meaning
1
Water level sensor has scaled up at normal level
2
Operating level sensor has been detected but not lower sensor (scaled
up)
3
Overfill level sensor has been detected but others have not (scale)
4
Danger level sensor detected
5
Overheated. Thermistor or potentiometer problem
6
Boiler has failed to fill in allotted time
7
The temperature sensor disconnected or element failed
8 or 9
Fault on temperature sensor
10
Element faulty or system fault
11
Water supply has been interrupted and the level has fallen to a point at
which the element could be damage
12
Machine has over boiled and the level has fallen to a point at which the
element could be damage
SERVICE/TECHNICAL SUPPORT:
Tel: 01704 502911
To ensure your service enquiry is handled as efficiently as possible, please have the following
information available;
- Brief description of problem
- Product Type (model)
- Serial Number (label on right-hand side of machine). This is essential