Machine makes a Gearbox drive not Loosen gearbox
ratcheting noise when engaged with airlock and gearbox
turned on. rotor connection. stabilizers. Align
gearbox and airlock
perpendicular to
each other.
Low oil level in gearbox. Have the gearbox
inspected and
repaired by a
qualified technician
if necessary.
Decreased material Worn airlock seals. Inspect seals for
throw. tears or cuts. See
maintenance section
to replace or adjust
as necessary.
Kink in hose. Run hose as straight
as possible to help
maintain production.
Excess air leaking into Inspect seals for tears
hopper. or cuts. See mainten-
ance section to
replace or adjust as
necessary.
Machine does not run No power. Check source of
electrical power.
Possible tripped
circuit breaker.
Main panel circuit Push to reset.
breaker tripped.
TROUBLESHOOTING