31
TROUBLESHOOTING
THE FORCE
/
1
Troubleshooting Cont.
TROUBLESHOOTING
Air, but no material, Slide gate closed. Open to operating
comes out of hose position.
Bridging (air pocket Turn machine “off”
in hopper). and disconnect from
electrical power.
Redistribute material
in hopper. Reconnect
to electrical power.
Remote rocker switch Replace with original
for agitator motor has factory part.
failed.
Circuit breaker tripped on Push to reset.
main panel.
Jam between blade of Disconnect electrical
agitator and airlock. power. Remove
insulation material
from hopper. Locate
jam and remove
material with pliers.
Blower does not operate. Blower toggle switch on Switch toggle to “on”,
main panel Is “off”. use remote box to
operate.
Remote rocker switch Replace with original
for blower motor has factory part.
failed.
Loose power cord/extension Check condition of
cord at electrical system. electrical plug blades.
Loose wire in electrical Have the system
system. inspected and repaired
by a qualified technician.
Worn brushes in blower motor
Have the brushes
inspected and replaced
by a qualified technician.
Problem Likely Cause Remedy