46
» Program DHCP
If you do not have a DHCP server or do not want to use this option, do not enable it and follow the next steps, where
network mask, gateway, etc. will be added manually and not received from the connected network.
Enter + 831 + Enter
After the command, using the keyboard keys, enable option
1
(mark 1) and press the
Enter
key to conrm.
» Program the network mask
Enter + 8130 + Enter
After the command, type the network mask number and press the
Enter
key to conrm.
» Program the gateway
Enter + 8140 + Enter
After the command, type the gateway number and press the
Enter
key to conrm.
» Program DNS servers for Ethernet
Enter + 815 + S + Enter
, where S = 1 or 2 (Server 1 or Server 2)
After the command, type the DNS1 server number and press the
Enter
key to conrm.
» Program the Heartbeat Ehernet interval (link test)
Enter + 816 + TTM + Enter
, where TTM = time interval varying from 000 to 255 minutes (factory default:)
5 minutes
)
» Exit the programming mode with the installer password
Installer password (factory default:
9090
)
» Check the connection to the IP Receiver service
Press the
Menu
key, navigate through the arrow keys, access the
Connections
option and check if the mark for the
Eth
option:
IP1
and/or
IP2
is enabled. If yes, the alarm center is connected via Ethernet with the IP receiver software through
the IPs that were enabled.
Monitoring by GPRS
The alarm center can report events via 2G/3G channel – XAG 8000 module required, for monitoring companies, and sending
events to monitoring companies will use the GPRS channel to send to IP addresses, as well as the Ethernet connection. The
commands to be programmed are as follows:
Obs.: after entering each command and conrming with the
Enter
key, two quick beeps should be heard, indicating that the
programming was accepted, otherwise, there was an error.
» Enter in programming mode with the installer password
Enter + installer password
(factory default:
9090
)
» Program monitoring account
Enter + 15 + PP + Enter
, where PP = partition from 01 to 16
After the command, type the monitoring account number with 4 digits and press the
Enter
key to conrm.
» Program the reporting mode.
Enter + 17 + 4 + 0 + 0 + Enter
» Program communication priority (2G/3G only)
Enter + 19 + 1 + Enter
» Program destination IP
Enter + 801 + I + Enter
, where I = 1 or 2 (destination IP 1 or destination IP 2)
After the command, type the IP number of the monitoring company 1 (example: 192.168.001.100) and press the
Enter
key to conrm.
» Program IP network communication port
Port 1 = Enter + 802 + 1 + Port number with 4 digits + Enter
Port 2 = Enter + 802 + 2 + Port number with 4 digits + Enter