ADDED HEAT SECTION INSTRUCTIONS
A
.UNPLUG BELT EXIT PLUG FROM MAIN PANEL
B
.UNBOLT EXHAUST MOUNTING BRACKET FROM DRYER
C
.UNBOLT EXIT EXTENSION AND PULL BACK FROM
DRYER
D
.INSTALL NEW BLOWER MOTOR PULLEY PROVIDED
E
.CUT BURNER HOOD OPENING AS PER DETAILED
INSTRUCTION SHEET
F
.POSITION EXTRA 4' HEAT SECTION IN PROPER
LOCATION. LEVEL AND FASTEN LATCHES
G
.BOLT EXIT EXTENSION TO NEW HEAT SECTION
H
.CAREFULLY PULL AND EXTEND EXHAUST DUCTING
UNTIL IT CAN BE REMOUNTED IN NEW NOTED POSITION
I
.INSTALL BELT EXIT PLUG SPLICE TO EXISTING PLUG
AND PLUG INTO MAIN PANEL
J.
REMOVE SOLID PAN FROM LINT FILTER DRAWER ON
ADDITIONAL HEAT SECTION SIDE OF DRYER AND
REPLACE WITH SCREENED FILTER
NOTE
:ALL NECESSARY HARDWARE,PLUG WIRE AND
EXHUAST DUCT MOUNTS HAVE BEEN PROVIDED IN
ORDER TO NEATLY FINALIZE RETROFIT
MD8
ADDING 4 ft Section in the field
ADDITIONAL 4' HEAT SECTION
Remove Exhaust
Mount
Extra 4' Heat
Change Blower
Motor Pulley
Blower Motor
Infeed
Infeed
Infeed
by Interchange
Extra 4' Heat
Belt Exit Motor
Exhaust