EasyManua.ls Logo

Intergas Comfort Touch User Manual

Intergas Comfort Touch
140 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
COMFORT TOUCH

Other manuals for Intergas Comfort Touch

Question and Answer IconNeed help?

Do you have a question about the Intergas Comfort Touch and is the answer not in the manual?

Intergas Comfort Touch Specifications

General IconGeneral
TypeSmart thermostat
ConnectivityWi-Fi
Control via AppYes
CompatibilityIntergas boilers
DisplayTouchscreen
LanguagesDutch, English
Programming7-day programmable, Geolocation

Summary

Installation Manual

Turn your boiler off

Turn your boiler off using the switch. Always unplug the boiler before installing the thermostat.

Positioning the thermostat

Position the thermostat away from draughts, heat sources, and direct sunlight at the correct height.

Fixing the back plate to the wall

Fix the back plate to the wall using rawlplugs and screws or M3 bolts for a junction box.

Wiring the thermostat

Insert wires into the connector, ensuring wire cross-section is between 0.2 and 0.75 mm².

Connecting thermostat to boiler

Connect the thermostat to the boiler using a cable up to 50m, consulting the boiler manual for instructions.

Mounting thermostat on back plate

Slip the thermostat onto the back plate along the top edge and click it into place along the bottom edge.

Troubleshooting

Blank Screen

Troubleshoot a blank screen by plugging in the boiler and checking wiring and connection.

Internal error thermostat

An 'E' error code indicates a hardware error; the thermostat will restart or may need replacement.

Flashing 'F'

Boiler Fault

An 'F' display indicates a boiler fault; consult the boiler manual for error code meanings.

Flashing ' ' '

Boiler Not Smart Power Compatible

A flashing dot indicates the boiler is not Smart Power compatible and the thermostat will not work.

Flashing 'Ot'

OpenTherm Communication Error

Flashing 'Ot' means OpenTherm communication between thermostat and boiler is not responding.

Flashing 'FILL'

Low System Pressure

Flashing 'FILL' indicates low system pressure; the system may need topping up. Consult boiler manual.

User Manual

Standby Mode

Standby mode shows the current room temperature or is hidden. Boiler is in standby, no heat required.

Active Mode

Boiler Heat Required

Active mode indicates the boiler is on and heat is required, displaying the current temperature.

Temperature Adjustment

Setting Desired Temperature

Tap the dot to activate '+' and '-' buttons to set the desired temperature.

Control and Info Panel

Accessing Main Panel

Touch '+' and '-' buttons simultaneously for 2 seconds to open the main panel for control or info.

Control Panel

Adjusting Thermostat Settings

Access control panel to adjust settings by touching '+' and '-' buttons; confirm selections with the centre dot.

Standby

Displaying Room Temperature

Set thermostat to hide or display current room temperature permanently (ON/OFF).

Brightness

Adjusting Display Brightness

Tap '+' or '-' buttons to adjust display brightness to desired level (10 levels available).

Calibration

Temperature Calibration

Correct measured temperature by up to +/-4 °C in 0.1 °C increments to compensate for position.

Celsius/Fahrenheit

Unit Selection

Select either Celsius or Fahrenheit as the desired unit for temperature display.

Displayed temperature

Temperature Display Format

Change how measured room temperature is displayed (0.1°C or 0.5°C).

Control Settings

Control Response Time

Select control response time (e.g., 'slow') for different heating systems like underfloor or radiators.

Remote Response

Display Illumination

Set display to illuminate when adjusting temperature remotely via the Comfort Touch app.

Booster

Booster Function

Enable or disable the booster function from a connected Xtend for enhanced heating.

Info panel

Consulting Thermostat Values

Consult certain thermostat values by stepping through menus using '+' or '-' buttons.

Software version

Viewing Software Version

View the current software version of your thermostat.

Water temperature requested

Consulting Requested Water Temperature

Consult the requested water temperature, not available when Xource is connected.

Water temperature measured

Consulting Measured Water Temperature

Consult the currently measured water temperature, not available when unknown.

Maximum requested water temperature

Setting Maximum Water Temperature

Consult the maximum requested water temperature, adjustable at the boiler when necessary.

Outside temperature

Consulting Outdoor Temperature

Consult the currently measured outdoor temperature, not available when unknown.

CH pressure

Consulting CH Pressure

Consult the CH pressure, only visible when thermostat is set to °C and not available when unknown.

'AUTO' control settings

AUTO Control Response Time

When AUTO is selected and Xtend is connected, consult the selected control response time.

Active appliance

Identifying Active Appliance

See which appliance is currently active: CH boiler, heat pump, or both.

Cleaning Mode

Activating Cleaning Mode

Activate cleaning mode (screen lock) by touching the dot for 2 seconds; it disengages automatically.