EN: Installation Sheet 
Description 
ATS1210(L)E and ATS1211E are eight-zone data gathering 
panels for the Advisor Master system. 
Mounting the unit 
The DGP PCB can be mounted in any existing ATS series 
enclosure that supports the BB format. The DGP can also be 
mounted in one of the following separate housings: ATS1644 
(plastic), ATS1647 (large, plastic) and the ATS1643 (metal). 
The housings with mounting holes (items 1) are shown in 
Figures 2 to 4. Items 2 and 3 indicate the mounting hole for the 
pry-off tamper. All dimensions are given in mm. 
Figures 2 to 4 legend 
Item Description 
Figure 2  ATS1643 small metal housing 
Figure 3  ATS1644 small plastic housing 
Figure 4  ATS1647 large plastic housing  
(1)  Housing mounting holes 
(2)  Mounting holes for ST580 tamper switch 
(3)  Mounting holes for pry-off tamper 
Wiring 
J1: Databus and tamper connection 
COMMS +, −: 12 VD power supply. It is recommended that 
where the distance between an ATS121x and the nearest 
device is more than 100 meters, a separate power supply must 
be used. 
COMMS D+, D−: Positive and negative data connection of the 
system databus. Units can be up to 1.5 km from the four-lift 
DGP or the ATS control panel, depending on the cable used. 
See the ATS control panel installation guide for details. 
TAMP T, C: Connect the enclosure tamper switch across these 
terminals (tamper switch requires normally open contacts). 
J5/J6: Zone connection 
Each zone requires a 4.7 kΩ end-of-line resistor (1 or 2, 
depending on single or dual zone monitoring programmed in 
ATS control panel). 
J2: Output expanders 
+12 VDC supply and open collector or data output for output 
connection to ATS1810, ATS1811 and ATS1820 output cards 
via 10-way cable supplied with the output card. Up to sixteen 
outputs are available with 8-way or 16-way open collector 
cards (4-way and 8/16-way output cards cannot be used 
together on the same DGP). 
J7: Input expanders 
Interface to ATS1202 input expander. 
J12: Earth connector 
Earth wires from all pieces of equipment must be earthed at 
one system earth. For more details see Advisor Master 
Installation Guide. 
Jumpers and DIP switches 
J3: Internal/external tamper jumper 
INT (see Figure 1, item 1): The front and back tamper switches 
of the PCB are used (in combination with ATS1644 plastic 
housing). 
EXT (see Figure 1, item 2): Tamper connections on connector 
J1 (T, C) are used for an external tamper switch (in 
combination with ATS1643 and ATS1647 housings).  
J11: TERM jumper 
The “TERM” jumper is placed is on the first and last devices on 
the system databus. In a “star” wiring configuration, the 
“TERM” link is only fitted on the devices at the ends of the two 
longest system databus cable runs.  
ADDRESS: DIP switch 
DIP switches 1 to 4 are used to identify the DGP number. See 
Figure 1 for more details. 
LEDs 
RX: LED flashes to indicate polling data is being received on 
the system databus from the ATS control panel. If the LED 
2 / 16    P/N 1077869 • REV 1.0 • ISS 31OCT11