FP/FR1100/1200/
2000 Series
Analogue addressable fire panels,
repeaters and emulators
Installation and
Commissioning Manual
Revision 6.2: February 2003

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Interlogix FP 2000 Series and is the answer not in the manual?

Interlogix FP 2000 Series Specifications

General IconGeneral
BrandInterlogix
ModelFP 2000 Series
CategoryFire Alarms
LanguageEnglish

Summary

3 Technical Specifications

3.1 General Specifications

Covers loop capacity, zone capacity, LCD screen details, and indicator types for the fire panels.

3.2 Panel Specifications

Details standard outputs, inputs, power supply characteristics, panel operation, and environmental ratings.

3.2.1 Standard Outputs

Specifies the 24V DC supervised outputs for alarm devices, fire routing, fire protection, and fault routing.

3.2.3 Power Supply Characteristics

Outlines input/output voltages, battery standby, and supervisory fault conditions for various panel models.

6 Field Connections

6.1 Loop, Output and Input Connections

Details loop, input, and output connections for FP12xx and FP2xxx series panels.

6.1.1 FP12xx

Diagram showing position of inputs, loops, and relay connections for FP12xx series panels.

6.1.2 FP2xxx

Diagram showing position of inputs, loops, and relay connections for FP2xxx series panels.

6.2 Connections

Provides detailed connection instructions for loops, relays, inputs, and communication ports.

6.2.1 Loop Connections

Explains Class A, Class B, and Class AB loop connection configurations using jumpers.

6.2.3 Supervised Outputs A

Describes the 24 VDC supervised outputs and their connections on the SD2000 I/O board.

6.4 Power Supply Connections

Provides connection details for 24V FR2xxx models, 230V FP/FR1xxx/FR2000, FP1216EN/FP1264, and FP2xxx models.

6.4.2 230 V Version (FP/FR1xxx/FR2000 Models – Except FP1216EN & FP1264)

Details mains connection and power supply connections for specific 230V panel variants.

6.4.2.1 Mains Connection

Explains the mains connection via a terminal block with fuse, emphasizing polarity and dedicated circuit.

6.6 Network Connections

Details network interface cards, extension modules, and serial communication networks.

6.6.1 NC2011/NC2051 ARCNET Network Cards

Explains ARCNET interface cards for networking FP2000 series panels and FR2000 repeaters/emulators.

8 Commissioning a FP2000 Series Fire Panel

8.1 Before Switching On

Provides a checklist of pre-commissioning checks including visual inspection, harness connections, and earth bonding.

8.2 Procedure for Switching On

Guides through the procedure for switching on the panel, checking initial display, and fault reporting.

Appendix A: DIP Switch Settings on Host PSU Board (FP/FR2xxx)

Appendix B: Software Selectable Options (FP/FR1xxx)

Appendix C: Operation Modes