FP/FR1100/1200/2000 V6: Installation and Commissioning Manual 55
A
PPENDIX
A:
DIP
SWITCH SETTINGS ON HOST
PSU
BOARD
(FP/FR2
XXX
)
On host power supply board:
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 OPTION
ON Aritech (950 Series)
OFF Sentrol (2000 Series)
OFF OFF EN Operation
OFF ON VdS Operation
ON OFF NEN Operation
ON ON EP Operation
Language Group
1 2 3
OFF OFF OFF English English English
OFF OFF ON Italian Lithuanian Lithuanian
OFF ON OFF Dutch (Belgium) Polish Danish
OFF ON ON Portuguese Hungarian Swedish
ON OFF OFF Dutch (Holland) Czech Norwegian
ON OFF ON German Slovakian Finnish
ON ON OFF French Russian Estonian
ON ON ON Spanish Latvian
ON = Upper position
OFF = Lower position
The location of the DIP-switch is shown in Figure 7 (position 12).
Note: If a SD1200 or SD2000 is mounted in the panel VdS mode is not fully supported.