Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 149
⢠AG symbolic: The same as symbolic, but for area groups.
See Advisor Advanced User Guide for more information on area selection.
2.2.1.n.3.16 LCD backlight
16 Status ind.
>Always on<
LCD backlight option defines when the keypad display backlight is lit. There are
the following options available:
⢠Always on: LCD backlight never switches off.
⢠Normal: LCD backlight switches off after the particular idle time.
⢠Excl. entry: LCD backlight is off during the entry time, until a key is pressed.
Note: The backlight timeout depends on the particular keypad firmware.
2.2.1.n.3.17 ACK on keypad
The ACK on keypad option allows you to select an additional LCD keypad that
displays an acknowledgement prompt after the system is unset using the
selected non-LCD keypad or reader.
Note: This option is only available for non-LCD keypads and card readers.
See also ā4.1.n.6.26 ACK on keypadā on page 178 for more details.
2.2.1.n.3.18 EE 1 buzzer
If the option is set to Yes, the buzzer of the selected keypad is active during
entry/exit time 1.
See ā2. Entry/Exit 1ā on page 45 for more details.
2.2.1.n.3.19 EE 2 buzzer
If the option is set to Yes, the buzzer of the selected keypad is active during
entry/exit time 2.
See ā18. Entry/Exit 2ā on page 47 for more details.
2.2.1.n.3.20 1+3 keys
If the option is set to Yes, the combination of 1 and 3 keys allows you to raise a
panic alarm.