Chapter 5: Menu reference
256 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
8.8.8 Mon 3 HC out
8 Mon 3 HC out
>Enable<
Monitor 3rd high current output option defines whether high current output 3 is
monitored or not.
Output 3 mode depends on the panel model. See “Outputson page 30 for
details.
8.8.9 Card number
9 Card number
>Basic<
Select the way the card number is represented in the control panel.
Basic. The card number is represented in the standard Advisor Advanced
format.
Titan. The card number is represented in the extended Titan format.
8.8.10 Anonymize Log
10 Anonymize Log
> <
The menu allows you to set a time period, after which the user details are
removed from a log entry.
The allowed range is 0 to 60 days, 0 means the functionality is disabled. The
default value is 30 days.
8.9 Timed Unset / ATM
1>Delay
0
The menu allows you to configure the ATM (automated teller machine) interface.
8.9.1 Delay
1 Delay
> <
The option value is the time between the first and the second ATM user code
entering. At the end of the programmed delay period the ATM user is be
prompted to re-enter the code.
The allowed range is 0 to 15 minutes. 0 means that the ATM user code can be
entered twice without any delay. The default value is 0.

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals