EasyManuals Logo

Interlogix ATS3500A-IP-MM Installation And Programming Manual

Interlogix ATS3500A-IP-MM
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #333 background imageLoading...
Page #333 background image
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 327
Appendix B
Advisor Advanced
reporting codes
Table 33 below shows descriptions of SIA, CID, and VdS reporting codes used in
Advisor Advanced.
Table 34 on page 332 lists allowed values for the appropriate reporting codes.
Table 33: SIA, CID, and VdS reporting code descriptions
#
SIA
code
VdS
code
CID
code
Function
Note
Reporting
priority
1.
AN
0xB0
R393
Detector dirty restore
Low
2.
AR
0xB2
R301
AC restore
Low
3.
AS
0x30
E393
Detector dirty
Low
4.
AT
0x32
E301
AC trouble
Medium
5.
BA
0x22
E130
Burglary alarm
Alarm / input in mask /
trouble when set
Medium
6.
BB
0x51
E570
Burglary bypass
Alarm inhibit
Low
7.
BC
0x52
E406
Burglary cancel
Cancel alarm by user / key /
remotely
Low
8.
BJ
0xB0
R381
Detector supervision
restore
Low
9.
BR
0xA2
R130
Burglary restore
Low
10.
BT
0x30
E380
Burglary trouble
Input in mask / trouble when
unset
Low
11.
BU
0xD1
R570
Burglary unbypass
Alarm uninhibit
Low
12.
BV
0x00
E139
Alarm confirm
ACPO
Medium
13.
BW
0x80
R139
Restore confirmed
alarm
ACPO
Low
14.
BZ
0x30
E381
Detector supervision
Low
15.
CF
0x51
E408
Forced closing
Set by user / by key
Low
16.
CG
0x62
E456
Part set
Part set by user / by key /
remotely
Low

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals