Chapter 5: Menu reference
246 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
15 minutes
30 minutes
1 hour
2 hours
3 hours
4 hours
See “Autoseton page 91 for more details.
The user must have a privilege for full setting to be allowed to postpone the
autoset. See “3.2.n.6 User group optionson page 169 for more details.
8.5 Access options
1>Access timers
2 DGP options
The menu contains various access control options.
8.5.1 Access timers
1>Card to PIN
127
The menu contains access timer settings.
Note: All timers are programmed in seconds. The allowed ranges are 0 to 127 s.
8.5.1.1 Card to PIN
1 Card to PIN
> <
This setting is only applicable when a user is required to present a card and enter
a PIN to gain access.
The Card to Pin Time is the amount of time allowed between presenting a valid
card to a door reader and entering a valid PIN (last digits) on the keypad. If the
PIN is not entered before the time expires, the user will need to repeat the door
opening function.
8.5.1.2 Two cards
2 Two cards
> <
This setting is only applicable when two users must present their card or PIN to
open a door or when a user is identified as a visitor or guard and must be
accompanied.
The Two cards time is the amount of time allowed between the first user
presenting a card or entering a PIN and the second user presenting a card or
entering a PIN. If the second card/PIN is not presented before the time expires,
the door opening function will have to be repeated.