Concord 4 Installation Guide 7
Sensor group characteristics
Table 10 below shows what the sensors on your Concord 4 system do. Every sensor is assigned to a group, and this
table specifies those groups and functions. Every device must be assigned to one of these groups.
Note: The “X” marks in the table represent characteristics present in a group.
Table 10: Sensor group characteristics
24-hour audible fixed emergency
buttons
24-hour audible portable emergency
buttons
24-hour silent fixed emergency
buttons
24-hour silent portable emergency
buttons
24- hour auxiliary sensor, such as
pendant panic or holdup button
Auxiliary
24-hour auxiliary emergency button,
siren shutoff confirms CS report
Auxiliary
24-hour portable auxiliary alert
button
Auxiliary
24-hour portable auxiliary button,
siren shutoff confirms CS report
Auxiliary
Special belongings, such as gun
cabinets and w all safes
Special belongings, such as gun
cabinets and w all safes
Entry and exit doors that require a
standard delay time
Supplementary
Extended Delay
Garage doors and entrances that
require extended delay time
1,5
Drivew ay gates and entrances that
require a tw ice extended delay time
1,5
Exterior doors and w indows
Interior doors (hardwired)
Follower
Interior PIR motion sensors
1
(RF
w ireless)
Follower
Interior doors (hardwired)
Follower
PIR motion sensors 1 (RF w ireless)
Follower
Instant interior cross-zone # PIR
motion sensors
1, 2
Follower
Supplementary
Extended Delay