xGenConnect Installation and Programming Guide  133 
9.  Click System Event Reporting. 
 
10. Select the channel group to send system events (e.g. low battery). 
Next 
•  Perform tests on each of the communication paths to verify they are 
functioning correctly. 
•  Program Channels. 
•  Program Channel Groups. 
•  Verify Number of Attempts, next channels (back-up channels), and multi-path 
reporting function correctly. 
Programming Instructions for UltraSync 
Pre-conditions 
At least one user has been given a username and PIN code (see “Programming 
Instructions for Users” on page 109). 
xGenConnect is connected to internet and has been allocated an IP address 
(see “Programming Instructions for Communicator” on page 130, IP Config). 
Notes: 
UltraSync provides a secure VPN connection to your xGenConnect system over 
the internet. You will need to provide your xGenConnect serial number, Web 
Access Passcode, and a valid Username and PIN code that exists in your 
xGenConnect system. These codes provide multiple levels of security for the 
connection. 
The Web Access Passcode is needed for: 
•  Web console over the internet via a secure VPN 
•  UltraSync+ app 
•  DLX900 software connecting over IP, in addition to Download Access Code 
The Web Access Passcode is NOT needed for: 
•  Email services  
•  Web console over a local LAN connection 
Once UltraSync is set up, you may connect to your xGenConnect system using 
the UltraSync+ app on your smartphone or tablet. This may require a separate