xGenConnect Installation and Programming Guide  137 
Then we click to Event List 2 and enter the name “Informational”. Tick Opening 
and Closing, and Autotest Report. 
 
Programming Instructions for Channels 
Goal 
Set up communication paths and destinations for delivering event messages. 
Pre-conditions 
Communicator must be programmed (see “Programming Instructions for 
Communicator” on page 130). 
Event Lists must be programmed (see “Programming Instructions for Event Lists” 
on page 135). 
Notes 
•  Area Account Number will take priority over Account Number entered here for 
Zone events. If no Area Account Number is entered then this number will be 
used instead. 
•  Next Channel must be a higher value than the current Channel Number. 
Circular loops are not permitted. 
•  Take note of the Sequence Attempts under Communicator > System Event 
Reporting (6.11.2). This is the number of times xGenConnect will attempt the 
sequence of Channels you set up in this section. 
•  Channel set up for push notifications is automatically performed by the 
UltraSync+ app when required. The panel will assign the next available 
channel and matching event list number. No configuration via the web pages 
or DLX900 is required. 
 
Event
System / Area
Channel Group 1
Channel Group 1
Channel 1
Channel 4
Channel 6
Menu 6.11.1.1 or 4
Event sent to 
Channel Group
Menu 18 – Channel Groups
Menu 5 – Channels Menu 17 – Event Lists
Each channel checks to 
see if the event is on its 
Event List, if yes it will 
attempt to send, if not 
then it stops.
Channel Group sends event 
to   Channel it containsevery
Channel 1
Control Room 1
Channel 4
Control Room 2
Channel 6
Email
Event List 1
Critical
Event List 2
Informational
Event List = 1
Event List = 1
Event List = 2
Alarms
Bypass & Restore
AC Fail
Open & Closes
Autotest