Congratulations
You have made the right choice in purchasing a Pool and Spa Timer
that provides convenience as well as energy savings and it is designed for
indoor or outdoor use.
SAVE THESE IMPORTANT SAFETY INSTRUCTIONS
• Do not permit children to operate the timer or pool/spa unless
they are closely supervised at all times.
• Install only on a GROUNDED 120VAC circuit protected by a
Ground Fault Circuit Interrupter.
• Test GROUND FAULT protection regularly. If it fails to reset, DO
NOT USE the pool or spa! Contact a qualified service technician.
• Always disconnect electricity before servicing this timer or
the equipment connected to it. THIS TIMER IS NOT TO BE
USED AS A POWER DISCONNECT.
• Timer must be installed vertically at least 3 ft. above ground
level and at least 5 Ft. away from edge of pool or Spa.
• Equipment connected to this timer should not exceed capacity
of timer.
• Use timer only for its intended use as described in this manual.
The protective cover should always be in place.
Troubleshooting Guide
Symptom Cause(s) Corrective Action
No power at • No power to timer Check circuit breaker in panel.
timer’s receptacle
• Open GFCI Reset and test GFCI.
• Timer contacts open Turn timer to ON, check timer
setting and operation.
• Defective timer Replace timer.
Timer loses time • Power to timer is Check branch circuit that
not continuous timer is plugged in to.
• Defective timer Replace timer.
Timer’s receptacle • No OFF trippers in dial Check timer operation.
is “hot” (energized)
• Defective timer Replace timer.
at all times