Chapter 2 — Replacing Parts
To replace the SE1200 scanner
1 Open the CK30. For help, see “Opening the CK30” on page 9.
2 From the bottom cover, remove the four Phillips screws that attach
the scan engine assembly.
3 Lift the scan engine assembly away from the bottom cover.
Screw
(4 places)
SE1200 scan
engine assembly
Large scan mount
bracket
Screw
(2 places)
4 Turn the scan engine assembly over and remove the two Phillips screws
that attach the scan engine to the large scan mount bracket.
5 Disconnect the scan flex cable from the scan engine.
6 Assemble the new scan engine for replacement:
a
Remove the adhesive backing from the SE1200 visor and attach it to
the front of the scan engine.
b
Connect the scan flex cable to the scan engine. Make sure you
completely insert the scan flex cable up to the white alignment mark.
c
Thread the scan flex cable through the opening in the shield and set
the shield over the scan engine.
22 CK30 Handheld Computer Service Manual