Chapter 2 — Replacing Parts
Replacing the IT4000 Imager
To replace the IT4000 imager, you need the following tools and parts:
T10 Torx screwdriver
Small Phillips screwdriver
IT4000 imager assembly (P/N 073416S-001)
Phillips 4-20 x .250 thread-form screw (P/N 525023)
To replace the IT4000 imager
1 Open the CK30. For help, see “Opening the CK30” on page 9.
2 From the bottom cover, remove the three Phillips screws that attach
the IT4000 imager assembly.
3 Lift the imager assembly away from the bottom cover.
Screw
(3 places)
IT4000
imager
assembly
4 Insert the new imager assembly and attach it with the three Phillips
screws removed in Step 2.
5 Close the CK30. For help, see “Closing the CK30” on page 27.
Replacing the Tethered Scanner
To replace the tethered scanner, you need the following tools:
T10 Torx screwdriver
Small Phillips screwdriver
Small straight-slot screwdriver