Chapter 4 — Theory of Operation
Supported Scanners
Device Interface Type Support Status
DBP Supported in SE900 compatibility mode. EV10 1D imager
MDS MDS mode to be added in a future release.
DBP Supported in architecture, but not implemented. E1022/E1025
Decoded RSTTL Supported in architecture, but not implemented.
EL10 Micro-Mirror Laser DBP
Supported, but not released as a valid
configuration.
SE900 DBP
This is implemented, but not released as a valid
configuration.
SE900HS DBP
This is implemented, but not released as a valid
configuration.
SE1200 DBP Supported.
SE1200ALR DBP Supported.
I2 and IT4000 2D imagers 8-bit parallel pixel data Supported.
Tethered undecoded scanners:
1550C01xx
128x wands
DBP
Supported.
Supported.
Tethered decoded scanners:
1400
1551E
1553
1800 ScanPlus
Wand-emulation
Supported, but not released as a valid
configuration.
Tethered decoded scanners:
1400
1551E
1553
1555
1470B
1800 ScanPlus
Decoded RSTTL
Supported in a future release.
Supported.
Supported.
Supported in a future release.
Supported in a future release.
Supported in a future release.
DBP = Legacy laser scanner interface, using DBP, SOS, LAS_EN, and SCAN_EN signals.
MDS = High-speed serial SPI interface developed by Toulouse for transferring raw A/D data to the host processor.
RSTTL = TTL-level RS-232 from a scanner with built-in decode.
Wand-em = Wand emulation mode using only the DBP signal; used by scanners with built-in decode.
The CK30 platform uses the main processor to decode bar code
information from undecoded 1D laser, 1D CCD- and CMOS-based
imagers, and 2D imager input devices. The interface also supports serial-
output decoded scanners.