Appendix A — Specifications
100 CK3R and CK3X Mobile Computer User Manual
EA30 Area Imager Minimum Reading Distances
Minimum reading distances are measured in the dark (0 lux).
EA30 Minimum Reading Distances
EA30 Minimum Reading Distances
Symbology Density
Minimum
Distance
Maximum Distance
Code 39 0.10 mm/4
mils0.13 mm/5
mils0.50 mm/20
mils1 mm/40
mils
9.5 cm/3.74 in8
cm/3.15 in7
cm/2.76 in9.5
cm/3.74 in
10.5 cm/4.13 in14
cm/5.51 in45
cm/17.72 in62
cm/24.41 in
EAN/UPC 100% 0.33 mm/13 mils 6 cm/2.36 in 31.5 cm/12.4 in
cm
PDF417 10 mils
0.5 mm / 20 mils
1 mm / 40 mils
Data Matrix 10 mils
in
0" 28"24"20"16"12"8"4"
070605040302010
EAN/UPC
0.125mm/5 mils
4"
8"
0"
4"
8"
12"
12"
10
0
10
20
20
30
30