Chapter 3 — Troubleshooting and Maintaining the Printer
PF8d and PF8t Desktop Printer User’s Guide 59
If you are using Gap sensing or Continuous stock, this sensor MUST
be in the default, far-right position, or “Out of Paper”, “Media not
Loaded”, or other media fault errors may continually occur.
To locate and adjust the black mark/label stop sensor
1 Open the top of the printer.
2 Lift the printhead.
The black mark sensor is near the front of the printer, behind the
roller, in a groove that runs from the left side to the middle of the
printer. The sensor optics are visible as a small slit on the left, and
there is a ridged finger-notch to the right.
3 If the sensor is not all the way to the right, put your fingertip in
the ridged finger-notch and slide the sensor all the way to the
right. Do not touch the sensor itself, because natural finger oils
may dirty the optics.
4 Lower the printhead, close the printer, and try printing again.

Table of Contents

Other manuals for Intermec PF8T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec PF8T and is the answer not in the manual?

Intermec PF8T Specifications

General IconGeneral
Print technologyThermal transfer
Maximum resolution203 x 203 DPI
Core diameter25.4 mm
Ribbon length274.32 m
Maximum media length1727 mm
Maximum roll diameter127 mm
Supported paper width118 mm
Maximum media length (imperial)68 \
Supported paper width (imperial)4.65 \
RS-232 ports1
Standard interfacesUSB 2.0
Connectivity technologyWired
Form factorDesktop
Dimensions (WxDxH)168 x 218 x 116 mm
Flash memory4 MB
CertificationCE, FCC Class A, cULus, UL, GS, TUVGS, CCC, C-TICK, BSMI
Internal memory8 MB
Built-in barcodesMaxiCode, PDF417
Page description languagesEPL
Compatible operating systemsWindows 98/Me/2000/XP Pro/Server 2003/Vista
Storage temperature (T-T)40 - 104 °F
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)10 - 90 %
Power requirements100–240 V AC/50–60 Hz, 1.9 A
AC adapter output current3 A
AC adapter output voltage24 V
Weight and Dimensions IconWeight and Dimensions
Weight2000 g