TROUBLESHOOTING (continued)
LED PANEL
CODE
PROBLEM SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).
E90
ā¢
Noīwaterīīow.
ā¢
Turn off and unplug the control unit.
ā¢
Ensure the outlet cover grid is clean and free from obstructions.
ā¢
Clean or replace the cartridge, see Maintenance and Storage section.
ā¢
Ensureītheīin/outletīconnectionsīonītheīspaītubīandīīælterīpumpīareīnotī
blocked.
ā¢
Keep the spa water properly sanitized to ensure a clean and unclogged
īīīīīælterīcartridge.
ā¢
Press the button to turn off the unit. Release trapped air by
unscrewing the drain valve cap on the control base side with a coin.
īīīīAirīhasībeenīreleaseīonceīaīsteadyīstreamīofīwaterīisīīowingīoutīfromī
the drain valve. Wait for 15 seconds and screw the drain valve cap
back. Press the button to activate the control panel buttons, and
īīīīthenīrunītheīīælterīfunctionībyīpressingītheīīīīīīīīībuttonītoīpushīoutīanyī
remaining air in the system.
ā¢
If problem persists, contact Intex Service Center.
E91
ā¢
Dirt or scale on titanium plates.
ā¢
Low salt level / No salt.
ā¢
Electrolytic cell cord is loose.
ā¢
Possible electrolytic cell failure.
ā¢
Remove the electrolytic cell for inspection. Clean it if necessary. See
āMaintenanceā.
ā¢
Add salt. See āSalt Level Informationā.
ā¢
Ensureīthatītheīcellīcordīisīpluggedīīærmlyīintoītheīcellīreceptacle.
ā¢
Contact Intex Service Center. Replace the cell if needed.
E92 ā¢
High salt level.
ā¢
ī Partiallyīdrainītheīpoolīandīreīællīitīwithīfreshīwater.īSeeīāSaltīLevelī
Informationā.
E94
ā¢
Water temperature too low.
ā¢
If the ambient temperature is below 4°C (39°F), we recommend not to
use the spa.
ā¢
Turn off and unplug the control unit, add some warm water to raise the
spa water temperature above 5°C (41°F), then press the button to
heat up the water to the desired temperature.
ā¢
If problem persists, contact Intex Service Center.
E95
ā¢
Water temperature is
around 50°C (122°F).
ā¢
Turn off and unplug the control unit. When the water has cooled down,
plug the RCD and restart all over again.
ā¢
Turnītheīheaterīoff,īthenīpressītheīīælterīandījetībuttonsītoīlowerītheī
water temperature.
ā¢
If problem persists, contact Intex Service Center.
E96
ā¢
System Error.
ā¢
Turn off and unplug the control unit. Plug the RCD and restart
all over again.
ā¢
If problem persists, contact Intex Service Center.
E97 ā¢
Dry-īæreīProtection.
ā¢
Contact Intex Service Center.
E99
ā¢
Water temperature sensor broken.
ā¢
Contact Intex Service Center.
END
ā¢
After 72 hours of continuous
heating operation, the pump will
hibernate automatically. The
īīīrapidīheatingīandīwaterīīæltrationī
functions are disabled.
ā¢
ī Pressītheīīīīīīīīībuttonītoīre-activeītheīīælterīpump.ī