133
SAVE THESE INSTRUCTIONS
Page 22
(133) MODEL CS8111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 11/17/2011
English
SALTWATER SYSTEM OPERATION (continued)
OOPPEERRAATTIINNGG IINNSSTTRRUUCCTTIIOONNSS
6. Boost cycle
• If the test result is below 0.1ppm, press and hold “BOOST”
button for 5 seconds until the indicator lights up and the
L
ED display display “80”. This indicates that the saltwater
system has started copper ion and more chlorine sanitizer
production.
You can press and hold the “BOOST” button for another 5
seconds until the indicator is off, which will cancel the Boost
cycle.
Note: Once the system has started copper ion and more chlorine sanitizer
production, the boost button can’t be re-set until the power switch is off.
• The boost operating hours is 4 times the amount of time programmed into the
system, i.e. if your saltwater system operating time is 2 hours, the boost procedure
will run 4 x 2 = 8 hours. After boost procedure has been completed, the system
will automatically switch to the normal working mode.
• After a heavy rain or if the pool is dirty, press the “BOOST” button to shock the
pool again.
7. Test pool water regularly:
Once the copper level appears to be balanced, test the pool water every week
to maintain the proper sanitizer level.
It’s very important that the free chlorine is between 0.4-1.5 ppm and copper
ion concentration is between 0.1~0.2 ppm. When the copper level is below 0.1
ppm, repeat step 6.
NOTE: A High copper ion concentration may cause blonde hair to exhibit a
green hair. To prevent this, wear a swimming cap during swimming, and wash
hair with special shampoo after using the pool.
See “Troubleshooting Guide”.
8. Stand-by/power saving mode:
• When the cycle ends, the green “SLEEP” indicator on the
control panel lights up and the LED display flashes “93”.
The system is now in Stand-By mode. After a while, it
shuts down and sets itself in a Power Saving mode. The
system will automatically turn itself back on in 24 hours,
starting its daily cycle of chlorine production.
• The “SLEEP” indicator stays on, while the system is in the
Power Saving mode. The LED display however, goes blank
after 1 hour. Press any button ( or ) to view the last LED
code.
9. Running the pump alone without the Saltwater System:
To run the pump alone without the Saltwater System function,
press and hold both and buttons until you hear a
“beep”, the LED display will show “FP”. The pump is now
operating alone. NOTE: The pump cannot be operated alone
under an automatic timer mode. To stop the pump, manually
turn the switch OFF.
IMPORTANT: To keep the initial automatic operating cycle
setting of the Saltwater System, turn the switch ON, the LED
display will show “FP”, and then press until you hear a “beep”.
The LED display will now show the initial input hours and the Saltwater System
cycle will repeat again.