SECTION 2—PARTS AND INSTALLATION
Part No 1150695 19 Recessed Side Entry Bath Tubs
6. Opentheserviceaccesspaneltoaccesspumpelectricconnections(DetailA”).
7. Routeelectricallinethroughelectricallineroutinghole.RefertoElectricaland
PlumbingHookupLocationsontheTubonpage 17forthelocationofthishole.
8. Removethemotorcover(Detail“C”).
9. Connectground,neutralandhotwiresfromwalldirectlytomotor(Detail“D”).
FIGURE 2.6 Electrical Installation
Service Access Panel
Wall
Tub Wall
Pump
Motor
BLACK
WHITE
GREEN
DETAIL “A” - ACCESS PANEL DETAIL “B” - ELECTRICAL SCHEMATIC
Air Switch Line
Motor
Cover
Ground (GREEN)
Line (BLACK)
Neutral (WHITE)
Ground
Line
Neutral
DETAIL “D” - MOTOR END PLATE
DETAIL “C” - MOTOR COVER
115 V Electrical Hook-up