Wall Mounted Unit
Owner’s Manual
Models
Thank you for choosing INVENTOR air
conditioning system. For correct use of this unit,
please read this manual carefully and keep it for
future reference.
B2VI-09/B2VO-09
B2VI-12/B2VO-12
66129912898

Other manuals for INVENTOR B2VI-09

Questions and Answers

  • U
    ujonesAug 18, 2025
    Why is my INVENTOR B2VI-09 Air Conditioner remote not working?
    • M
      mark46Aug 18, 2025
      If your INVENTOR Air Conditioner remote controller isn't working, first, try pulling the plug out and reinserting it to address potential magnetic or electrical interference. Also, ensure the remote is within its operating range and not obstructed. Then, check the batteries and replace them if needed. Finally, make sure the remote itself isn't damaged.
  • J
    Justin DorseyAug 20, 2025
    Why is there moisture on my INVENTOR B2VI-09 Air Conditioner outlet?
    • D
      Diana RhodesAug 20, 2025
      If you see moisture on the air outlet of your INVENTOR Air Conditioner, it means the unit has been operating at high humidity for a long time, causing moisture to form on the grill and drip off.
  • A
    alexsanchezAug 23, 2025
    What to do if my INVENTOR B2VI-09 Air Conditioner won't start?
    • J
      Joshua CooperAug 23, 2025
      If your INVENTOR Air Conditioner isn't starting up, check the following: if the power is cut off, if the power plug is loose, if the circuit protection device tripped off, if the voltage is higher or lower than it should be, or if the TIMER is correctly used.
  • C
    Christopher GomezAug 26, 2025
    Why is my INVENTOR B2VI-09 Air Conditioner cooling/heating poorly?
    • M
      Martha PaulAug 26, 2025
      If your INVENTOR Air Conditioner's cooling or heating effect is poor, make sure the temperature setting is appropriate. Check if the inlet or outlet is blocked and ensure the filter is clean. Verify that windows and doors are closed, the fan speed isn't set too low, and there aren't any heat sources in the room.
  • A
    Andrew OrtegaAug 27, 2025
    Why is my INVENTOR B2VI-09 Air Conditioner not blowing air?
    • S
      Samantha GarzaAug 28, 2025
      There are several reasons why your INVENTOR Air Conditioner indoor unit might not blow air. In HEAT mode, airflow stops to prevent cold air when the indoor heat exchanger is very cold. Also in HEAT mode, frost may form on the outdoor heat exchanger when the outdoor temperature is low or humidity is high. In DRY mode, the fan may stop for 3-12 minutes to prevent condensate from vaporizing again.
  • J
    Joshua FordAug 30, 2025
    Why is my INVENTOR Air Conditioner leaking water outside?
    • D
      Derek SimonAug 30, 2025
      If you notice water leakage from your INVENTOR Air Conditioner's outdoor unit during cooling, it's likely condensate forming around the pipes and connection joints. During defrosting, it's thaw water flowing out. During heating, it's water dripping from the heat exchanger.
  • J
    John PatrickSep 2, 2025
    What to do if INVENTOR Air Conditioner is leaking water inside?
    • T
      Tina NguyenSep 2, 2025
      If your INVENTOR Air Conditioner's indoor unit is leaking water, it could be due to high humidity or condensate overflows. Also, check if the drain hose is loose.
  • J
    Joshua SmithSep 4, 2025
    Why is my INVENTOR B2VI-09 making noise?
    • C
      christophermcleanSep 4, 2025
      The noise you hear from your INVENTOR Air Conditioner's indoor unit might be the fan or compressor relay switching on or off. It could also be the sound of refrigerant flowing in reverse when defrosting starts or stops.
  • A
    Amanda AllenSep 7, 2025
    Why does my INVENTOR B2VI-09 smell?
    • B
      Brandon GrimesSep 7, 2025
      If your INVENTOR Air Conditioner emits odors, it's likely due to room smells (like furniture or tobacco) that have been taken into the unit. Consult an authorized service center for cleaning if the odors persist.
  • S
    Sean NelsonSep 9, 2025
    How to fix C5 Malfunction of connector jumper in INVENTOR Air Conditioner?
    • D
      Danny CollinsSep 9, 2025
      Check if the connector jumper contacts properly.

INVENTOR B2VI-09 Specifications

General IconGeneral
BrandINVENTOR
ModelB2VI-09
CategoryAir Conditioner
LanguageEnglish