Manifold
Valve
Multimeter
-76cmHg
Lo Handle
Charging hose
Manometer
Hi handle
Charging hose
Vacuum pump
Low pressure valve
Ø
Air purging and leakage test
Condensate drainage of outdoor unit (no for cooling only)
The condensate and defrosting water formd during heating
in the outdoor unit can be properly discharged by drainage
pipe .
Installation method:set the drain connection in 25 hole of the
chassis has been installed and then connect drainage pipe
with drain nozzle,so that condensate and defrosting waer can
be properly discharged
Chassis
Drain
connection
●
●
Install outdoor unit
Electric wiring
NOTE:
Wrong wiring may cause spare parts
After the cable fixed, make sure there
should be a free space between the
malfunction.
connection and connection and fixing
place on the lead wire.
3.
4.
5.
1.
2.
Disassemble the handle on the outdoor unit
Take off cord anchorage. Connect and fix
power connect cord (for cooling and heating
right side plate.
unit,connect and fix power connect cord and
signal control wire)to terminal block.
Fix the power connection cable with cord
anchorage,(for cooling and heating unit, use
the cord anchorage to fix the power connection
cable and the signal control wire).
Ensure wire has been fixed well.
Install the handle.
5
-1.0 10 pa
(-76cmHg)..
1. Connect charging hose of manifold valve to charge end of low pressure
valve (both high/low pressure valves must be tightly shut).
2. Connect joint of charging hose to vacuum pump.
3. Fully open handle handle of Lo manifold valve.
4. Open the vacuum pump to evacuate. At the beginning, slightly
loosen joint nut of low pressure valve to check if there
is air coming inside. (If noise of vacuum pump has
been changed, the reading of multimeter is 0) Then
tighten the nut.
5. Keep evacuating for more than 15mins and make
sure the reading of multi-meter is
6. Fully open high/low pressure valves.
7. Remove charging hose from charging end of low pressure valve.
8. Tighten bonnet of low-pressure valve. (As shown in Fig.10)
Fig.9
yellow-
green
blue
black
brown
Handle
3
power connect wire
wire clamp
22
yellow-
green
blue
black
brown
3
3
INDOOR/OUTDOOR
CONNECT FIG
INDOOR
OUTDOOR
power
connect
wire
3
yellow-
green
yellow-
green
blue
black
brown
blue
black
brown
3
power connect wire
wire clamp
3
INDOOR/OUTDOOR
CONNECT FIG
INDOOR
OUTDOOR
power
connect
wire
Handle
09.12K outdoor unit:
18
.24K outdoor unit: