BPD series PV pumping inverter Function parameters
35
Function
code
Name
Detailed description
Default
Modify
34: Speed deviation fault (dEu)
35: Maladjustment (STo)
36: Underload fault (LL)
37: Hydraulic probe damage (tSF)
38: PV reverse connection fault (PINV)
39: PV overcurrent (PVOC)
40: PV overvoltage (PVOV)
41: PV undervoltage (PVLV)
Alarm:
Weak light alarm (A-LS)
Underload alarm (A-LL)
Full-water alarm (A-tF)
Water-empty alarm (A-tL)
P08 Group Enhanced functions
P08.28
Number of fault
resets
0–10
5
○
P08.29
Automatic fault
reset interval
0.1–3600.0s
10.0s
○
3.2 Special function parameters
Function
code
Name
Detailed description
Default
Modify
P11 Group Protective parameters
P11.00
Phase loss
protection
0x000–0x111
LED ones place:
0: Input phase loss protection disabled
1: Input phase loss protection enabled
LED tens place:
0: Output phase loss protection disabled
1: Output phase loss protection enabled
LED hundreds place:
0: Input phase loss hardware protection disabled
1: Input phase loss hardware protection enabled
Depend
on
model
○